Product Description
CIM150 Immersit One Gallon
Immersit leak testing additive.
Recommended for aluminum, stainless and titanium.
Temperature range 5°C-25°C (41°F-77°F )
By lowering the surface tension and increasing the wetting ability of water, a leak in a pressurized immersed vessel will generate a steady stream of tiny bubbles instead of an occasional larger bubble as with untreated water. Small leaks will produce bubble indications that are impossible with normal water. The CIM Immersit series will not foam, will not support bacteria growth and are formulated to prevent corrosion. Although their use is recommended with deionized or distilled water, they are chelated to be compatible with mildly hard water. Biodegradable. They meet the requirements of ASTM E515 Sec 8 on Immersion Leak Testing.
Instructions:
Add IMMERSIT to deionized water in testing tank in ratio of 1 to 25% IMMERSIT in the testing tank.
Immersit mixes with water with minimal stirring.
Also available in larger sizes - call 1-800-288-3647 for more information